Formula 6.82
Water saturation determination (IE and CDN logs)
Input(s)
$R_{o}$: Hydrocarbon Formation Resistivity (ohm m)
$R_{t}$: Rock Resistivity (ohm m)
Output(s)
$S_{w}$: Water Saturation (fraction)
Formula(s)
$$ S_{w}=\left(\frac{R_{o}}{R_{t}}\right)^{0.5} $$
Reference(s)
Bassiouni, Z., 1994, Theory, Measurement, and Interpretation of Well Logs. SPE Textbook Series Vol. 4. Chapter 11, Page: 213.