Formula 4.103
Volume of fluid loss per unit area measured in a static test (acidizing)
Input(s)
$C_{w}$: Fluid Loss Coefficient, $\left(\mathrm{m} / \mathrm{s}^{1 / 2}\right)$
$\sqrt{t}$: Time root $\left(\mathrm{s}^{1 / 2}\right)$
$V_{s p t}$ : The Spurt Volume $\left(\mathrm{m}^{3} / \mathrm{m}^{2}\right)$
Output(s)
$V$ : Volume of Fluid Loss per Unit Ares $\left(\mathrm{m}^{3} / \mathrm{m}^{2}\right)$
Formula(s)
$$ V=V_{s p t}+2 C_{w} \sqrt{t} $$
Reference(s)
Williams, B. B., Gidley, J. L., \& Schechter, R. S. (1979). Acidizing fundamentals. Henry L. Doherty Memorial Fund of AIME, Society of Petroleum Engineers of AIME, Page: 42.