Formula 9.24
Pycnometer volume correction
Input(s)
$V_{k}$: Calibration Volume of Specific Gravity bottle (Pycnometer) $\left(\mathrm{mL}\right.$ or $\left.\mathrm{cm}^{3}\right)$
$T_{t}$: Test Temperature $\left({ }^{\circ} \mathrm{C}\right)$
$T_{k}$: Calibration Temperature $\left({ }^{\circ} \mathrm{C}\right)$
$\Omega$: Material Constant (for Ordinary Glass $=0.276 \cdot 10^{-4} /{ }^{\circ} \mathrm{C}$ )
$\Omega$: Material Constant (for Pyrex Glass $=0.156 \cdot 10^{-4} /{ }^{\circ} \mathrm{C}$ )
Output(s)
$V_{g}$: Real Volume of Specific Gravity bottle (Pycnometer) $\left(\mathrm{mL}\right.$ or $\left.\mathrm{cm}^{3}\right)$
Formula(s)
$$ \mathrm{V}_{\mathrm{g}}=\mathrm{V}_{\mathrm{k}}\left[1+\Omega\left(\mathrm{T}_{\mathrm{g}}-\mathrm{T}_{\mathrm{k}}\right)\right] $$
Reference(s)
Mihcakan, I.M., Alkan, K.H., Ugur, Z., Petroleum and Natural Gas Laboratory, Course Notes, I-Fluid Properties, ITU, Petroleum and Natural Gas Engineering, Istanbul, Turkey, 2001. Page 1-4.