Formula 10.27
Fraction of heat injected in latent form - Myhill and Stegemeier
Input(s)
$\mathrm{h}$: Height (ft)
$h_{t}$: Cumulative Height $(\mathrm{ft})$
k: Permeability $(\mathrm{mD})$
$k_{t}$: Cumulative Permeability $(\mathrm{mD})$
Output(s)
FMO: FMO (dimensionless)
Formula(s)
$$ F M O=\left(\frac{1}{h_{t}}\right) *\left(h+\frac{k_{t} * h_{t}-k * h}{k}\right) $$
Reference(s)
Ehrlich, R., 2016.PT E 531 Enhanced Oil Recovery. University of Southern California Lecture Notes.