Formula 3.28
Dimensionless shut-in time for MDH method
Input(s)
$\mathrm{k}$: Permeability $(\mathrm{mD})$
$\Delta \mathrm{t}$: Total Shut-in Time (day)
$\emptyset$: Porosity (fraction)
$\mu$: Viscosity $(\mathrm{cP})$
$c_{t}$: Total Compressibility $(1 / \mathrm{psi})$
A: Drainage Area $\left(\mathrm{ft}^{2}\right)$
Output(s)
$\Delta t_{D A}$: Dimensionless Shut-in Time (dimensionless)
Formula(s)
$$ \Delta t_{D A}=\frac{0.0002637 * k * \Delta t}{\phi * \mu * c_{t} * A} $$
Reference(s)
Ahmed, T., McKinney, P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 1, Page: 59.