Formula 10.1
Areal extent of heated zone
Input(s)
$Q_{i}$: Amount of Heat Injected (BTU)
$\mathrm{h}$: Height $(\mathrm{ft})$
$M_{r}$: Volumetric Heat Capacity of Reservoir $\left(\mathrm{BTU} / \mathrm{ft}^{3} \mathrm{~F}\right)$
G: Dimensionless Time Function (dimensionless)
$\Delta \mathrm{T}$: Temperature Differential $(\mathrm{K})$
$M_{s}$: Volumetric Heat Capacity of Steam $\left(\mathrm{BTU} / \mathrm{ft}^{3} \mathrm{~F}\right)$
$\alpha_{s}:$ Thermal Diffusivity $\left(\mathrm{ft}^{2} / \mathrm{d}\right)$
Output(s)
A: Area (acres)
Formula(s)
$$ \mathrm{A}=\frac{\mathrm{Q}_{\mathrm{i}} * \mathrm{~h} * \mathrm{M}_{\mathrm{r}} * \mathrm{G}}{43560 * 4 * \Delta \mathrm{T} * \alpha_{\mathrm{s}} * \mathrm{M}_{\mathrm{s}}^{2}} $$
Reference(s)
Prats, M. 1986. Thermal Recovery. Society of Petroleum Engineers, New York, Chapter: 5, Page: 44.