Formula 9.22
Liquid permeability (permeameter lab measurement)
Input(s)
$\mu$: Viscosity of Liquid Phase $(\mathrm{cP})$
$t$: Flowing Time (s)
$V$: Liquid Volume that flows in time $t-$ Burette Volume $\left(\mathrm{cm}^{3}\right)$
$P$: Pressure value that read from Pressure Gauge (Atm)
L: Plug Length $(\mathrm{cm})$
A: Open-Flow Area of the Plug $\left(\mathrm{cm}^{2}\right)$
Output(s)
$k$: Permeability (D)
Formula(s)
$$ \mathrm{k}=\frac{\mu \cdot \mathrm{V} \cdot \mathrm{L}}{\mathrm{A} \cdot \mathrm{P} \cdot \mathrm{t}} $$
Reference(s)
Mihcakan, I.M., Alkan, K.H., Ugur, Z., Petroleum and Natural Gas Laboratory, Course Notes, II-Properties of Porous Media, ITU, Petroleum and Natural Gas Engineering, Istanbul, Turkey, 2001. Page: 2-6.