Formula 6.84
Water saturation - Resistivity logs
Input(s)
$\mathrm{n}$: Saturation Exponent (dimensionless)
$R I$: Resistivity Index (dimensionless)
Output(s)
$S_{w}$: Water Saturation (fraction)
Formula(s)
$$ S_{w}=\left(\frac{1}{R I}\right)^{\frac{1}{n}} $$
Reference(s)
Core Laboratories. 2005. Formation Evaluation and Petrophysics, Page: 42.