Formula 4.112
Wellbore storage due to fluid level
Input(s)
$A_{a}$: Annulus Cross Sectional Area $\left(\mathrm{ft}^{2}\right)$
$\rho$: Wellbore Fluid Density $\left(\mathrm{lb} / \mathrm{ft}^{3}\right)$
Output(s)
$C_{F L}$: Wellbore Storage Coefficient (bbl/psi)
Formula(s)
$$ C_{F L}=\frac{144 * A_{a}}{5.615 * \rho} $$
Reference(s)
Ahmed, T., McKinney, P.D. 2005. Advanced Reservoir Engineering, Gulf Publishing of Elsevier, Chapter: 1, Page: 49 .