Formula 2.201
Stripping/snubbing calculations - Breakover point between stripping and snubbing
Input(s)
$D p$: Pipe or collar OD (in.)
P: Wellbore Pressure (psi)
$W_{d c}$: Weight of Drill Collar (lb/ft)
L: Drill Collar Length (ft)
BF: Buoyancy Factor (dimensionless)
$W_{d p}$: Drill Pipe Weight $(\mathrm{lb} / \mathrm{ft})$
Output(s)
F: Force created by wellbore pressure on Drill collar or pipe (lb)
W: Weight of Drill Collar (lb)
$W_{a d p}$: Additional weight required from Drill Pipe (lb)
$L_{b p}$: Length of Drill Pipe required to reach over breakover point (ft)
$L_{d s}$: Length of Drill string req to reach breakover point (ft)
Formula(s)
$$ \begin{gathered} F=D p^{2} * 0.7854 * P \\ W=W_{d c} * L * B F \\ W_{a d p}=F-W \\ L_{b p}=\frac{W_{a d p}}{B F * W_{d p}} \\ L_{d s}=L+L_{b p} \end{gathered} $$
Reference(s)
Formulas and Calculations for Drilling, Production and Workover, Second Edition, Lapeyrouse, Page: 139.