Formula 12.29

Inhibitor injection rate required

Input(s)

mw: Mass of Water (lb)

Xr: Rich Inhibitor Concentration (wt\%)

$\mathrm{Xl}$: Lean Inhibitor Concentration (wt\%)

Output(s)

m: Mass of Inhibitor (lb)

Formula(s)

$$ \begin{gathered} \mathrm{m}=\mathrm{m}_{\mathrm{w}} *\left(\mathrm{X}_{\mathrm{r}} /\left(\mathrm{X}_{1}-\mathrm{X}_{\mathrm{r}}\right)\right) \\ \mathrm{A}=\pi \mathrm{r}^{2} \end{gathered} $$

Reference(s)

John M. Campbell, Gas Conditioning and Processing, Campbell Petroleum Series, Oklahoma, 1992, Vol. 1, Page: 181 .